UV & Ozone in Cooling Towers

Sponsored by

Q: What are advantages and disadvantages in using UV light or ozone to treat cooling tower water?

A: The purpose of using UV or ozone is control of microorganisms in cooling tower water. Depending on characteristics of the makeup water, the control of the fouling, deposition and corrosion still needs to be addressed in some manner. We have three member companies that use ozone, electromagnetic pulses and ultrasonic waves to control microbiological formation. In all three cases, the suppliers state that you must control the concentration of the circulation water to prevent deposits.

UV:

Advantages

  • Low operating cost
  • No biological control chemicals to handle or store

Disadvantages

  • Cost of installation can be very high depending on pressure and circulation rate of the system
  • Need system to monitor UV light operation
  • Ineffective if water has even low levels of TSS

Ozone:
Advantages

  • Low operating cost
  • No biological chemicals to handle or store

Disadvantages

  • High initial installation cost
  • Need system to monitor generator operation
  • Maintenance cost can be a problem depending on the source water
  • Short contact time available for disinfection of system (periodic chemical treatment of alternate biocide may be necessary)
  • Chemicals for deposition and corrosion control may be necessary depending upon makeup water quality
  • Effectiveness in high TSS water can be a problem.

 


Cooling FAQs are provided by the Houston-based Cooling Technology Institute (CTI), a non-profit organization dedicated to improvement in technology, design, performance and maintenance of cooling towers and evaporative heat transfer systems (EHTS). They’re from the “Ask the Expert” column of CTI Journal. Contact: 281-583-4087 or www.cti.org

 

Sponsored by

 


TODAY'S HEADLINES

VA water utilities deptartment recognized for excellent performance

The VA Department of Health Office of Drinking Water award the city of Manassas Public Works and Utilities department the 2012 Excellence in Water Treatment Plant Performance award.

City of Seattle developing plans to protect local waterways, reduce stormwater runoff

Seattle Public Utilities is working on projects to reduce stormwater overflows and is preparing a 10-year plan to protect Seattle's waterways.

Great Lakes awarded $570K grant for protection, restoration efforts

The University of Michigan Water Center awarded 12 research grants, totaling nearly $570,000, for Great Lakes restoration and protection efforts.

Biosolids drying system to be installed at WI wastewater treatment plant

HUBER Technology has been selected to provide its BT Medium Temperature Belt Dryer for the Sheboygan Wastewater Treatment Plant in Wisconsin.

© 2013. PennWell Corporation. All Rights Reserved. PRIVACY POLICY | TERMS AND CONDITIONS